Sensitivity analysis of transmission tower-line system parameters under wind and ice loads

ZHANG Liang1, NIU Kai1, LUO Xianchao2, ZHANG Siyao2, PEI Haowei1, TANG Yake1, TIAN Li2*   

  1. 1. Economic Research Institute, State Grid Henan Electric Power Company, Zhengzhou 450007, Henan, China;
    2. School of Civil Engineering, Shandong University, Jinan 250061, Shandong, China
  • Published:2024-06-28

CLC Number: 

  • TM752
[1] 李正,杨靖波,韩军科,等. 2008年输电线路冰灾倒塔原因分析[J]. 电网技术, 2009, 33(2): 31-35. LI Zheng, YANG Jingbo, HAN Junke, et al. Analysis of the causes of the ice-related tower collapse on transmission lines in 2008[J]. Power System Technology, 2009, 33(2): 31-35.
[2] 刘凯铭. 大跨越输电塔-线体系脱冰和断线冲击动力响应分析[D]. 济南:山东大学, 2022. LIU Kaiming. Analysis of the dynamic response of de-icing and line breaking shocks in a large span transmission tower-line system[D]. Jinan: Shandong Univer-sity, 2022.
[3] 张来仪. 考虑地形影响的台风作用下输电塔-线体系响应分析[D]. 济南:山东大学, 2022. ZHANG Laiyi. Analysis of transmission tower-line system response under typhoon effects considering topography[D]. Jinan: Shandong University, 2022.
[4] 周梦瑶. 基于SMA阻尼器的大跨越输电塔-线体系风振控制研究[D]. 济南: 山东大学, 2021. ZHOU Mengyao. Research on wind vibration control of large span transmission tower-line system based on SMA dampers[D]. Jinan: Shandong University, 2021.
[5] 俞琪琦. 风致大跨越输电塔-线体系倒塌破坏研究[D]. 济南: 山东大学, 2016. YU Qiqi. Research on wind-induced collapse damage of large span transmission tower-line systems [D]. Jinan: Shandong University, 2016.
[6] STEWART J R. Ice as an influence on compact line phase spacing[R]. New York: Hanover Power Technologies Inc Schenectady, 1983.
[7] KEYHAN H, MCCLURE G, HABASHI W G. Dynamic analysis of an overhead transmission line subject to gusty wind loading predicted by wind-conductor interaction[J]. Computers & Structures, 2013, 122: 135-144.
[8] LASSE Makkonen. Modeling power line icing in freezing precipitation[J]. Atmospheric Research, 1998, 46(1): 131-142.
[9] 邹红波,宋家乐,刘媛,等. 基于PSO-SVM算法的输电线路覆冰舞动预测模型[J]. 振动与冲击, 2023, 42(3):280-286. ZOU Hongbo, SONG Jiale, LIU Yuan, et al. Prediction model for transmission line ice cover dance based on PSO-SVM algorithm[J]. Journal of Vibration and Shock, 2023, 42(3): 280-286.
[10] ZHOU L, YAN B, ZHANG L, et al. Study on galloping behavior of iced eight bundle conductor transmission lines[J]. Journal of Sound and Vibration, 2016, 362: 85-110.
[11] 徐文军,杨洪明,赵俊华,等. 冰风暴灾害下电力断线倒塔的概率计算[J]. 电力系统自动化,2011,35(1): 13-17. XU Wenjun, YANG Hongming, ZHAO Junhua, et al. Calculation of the probability of power line breakage and tower collapse in an ice storm disaster[J].Automation of Electric Power Systems, 2011, 35(1): 13-17.
[12] 杜运兴,卢心龙. 输电塔线体系风致覆冰脱落动力响应的研究[J]. 湖南大学学报(自然科学版), 2015, 42(11):88-94. DU Yunxing, LU Xinlong. Research on the dynamic response of wind-induced ice shedding in transmission tower systems[J]. Journal of Hunan University(Natural Sciences), 2015, 42(11): 88-94.
[13] 付朝阳. 地震下输电塔-线体系不确定性响应与倒塌分析[D]. 济南: 山东大学, 2021. FU Zhaoyang. Uncertainty response and collapse analysis of transmission tower-line systems under earthquakes [D]. Jinan: Shandong University, 2021.
[14] 张欣. 风荷载作用下大跨越输电塔-线体系的易损性分析[D]. 济南:山东大学, 2020. ZHANG Xin. Vulnerability analysis of large span transmission tower-line systems under wind loads [D]. Jinan: Shandong University, 2020.
[15] 李宏男,张文圣,付兴. 基于大数据深度学习的输电塔结构抗风易损性评估[J].土木工程学报, 2022, 55(9): 54-64. LI Hongnan, ZHANG Wensheng, FU Xing. Wind vulnerability assessment of power transmission tower structures based on deep learning from big data[J]. China Civil Engineering Journal, 2022, 55(9): 54-64.
[16] 徐震,张涛,葛向东,等.风荷载作用下输电塔-线体系不确定性分析[J].山东大学学报(工学版), 2021, 51(4): 99-105. XU Zhen, ZHANG Tao, GE Xiangdong, et al. Uncertainty analysis of transmission tower-line systems under wind loads[J]. Journal of Shandong University(Engineering Science), 2021, 51(4): 99-105.
[17] FU Xing, LI Hongnan, LI Gang. Fragility analysis and estimation of collapse status for transmission tower subjected to wind and rain loads[J]. Structural Safety, 2016, 58: 1-10.
[18] FU Zhaoyang, TIAN Li, LIU Juncai. Seismic response and collapse analysis of a transmission tower-line system considering uncertainty factors[J]. Journal of Constructional Steel Research, 2022, 189: 107094.
[19] 严波,盛金马,姜克儒,等. 猫头型输电塔在覆冰与风荷载下的动力稳定[J]. 科学技术与工程,2021,21(26):11166-11175. YAN Bo, SHENG Jinma, JIANG Keru, et al. Dynamic stability of cathead Transmission Towers under ice cover and wind loads[J]. Science Technology and Engineering, 2021, 21(26): 11166-11175.
[20] LIU Juncai, TIAN Li, MA Ruisheng, et al. Phenomenological hysteretic model for fixed-end steel equal-leg angle: Development and application[J]. Thin-Walled Structures, 2023, 183: 110335.
[21] 蒋兴良,易辉. 输电线路覆冰及防护[M]. 北京:中国电力出版社, 2002.
[22] 王建城,苏盛,盛小勇,等.输电线路多年一遇极值覆冰估计方法适用性分析[J].电网技术, 2015, 39(9): 2614-2620. WANG Jiancheng, SU Sheng, SHENG Xiaoyong, et al. Analysis of the applicability of a multi-year extreme ice estimation method for transmission lines[J]. Power System Technology, 2015, 39(9): 2614-2620.
[23] 中国人民共和国住房和城乡建设部. 110 kV~750 kV架空输电线路设计规范:GB 50545—2010[S].北京:中国计划出版社, 2010.
[24] 中华人民共和国建设部. 高耸结构设计规范: GB—J135—90[S]. 北京:中国建筑工业出版社, 1991.
[25] 刘春城,胡晓炜,曹玲. 基于ANSYS/PDS的覆冰荷载下高压输电塔可靠度分析[J]. 黑龙江电力, 2013, 35(2): 107-110. LIU Chuncheng, HU Xiaowei, CAO Lin. ANSYS/PDS-based reliability analysis of high-voltage transmission towers under ice-cover loading[J]. Heilongjinag Electric Power, 2013, 35(2): 107-110.